Nominal Input Voltage: |
220 – 240 VAC |
Line Current, nominal: |
0.25A MAX. |
Mains Frequency: |
50/60 Hz |
Rated Power factor: |
0.5(full load) @ 230V |
Power Loss in no load condition |
<0.3W |
Protection Class: |
II |
Output Current: |
0-1800 mADC |
(Remark) |
@CV12/24/48VDC 0-1800mA |
Output voltage: |
12/24/48VDC+/-5% |
Output Power: |
Maximum 24W |
No-load proof: |
Yes |
Short circuit protection: |
Automatic, reversible |
Overload protection: |
Automatic, reversible |
Over temperature protection: |
Automatic, reversible |
Ambient temperature range, ta: |
0 °C to +45 °C |
Max. case temperature at tc point: |
75 °C |
IP Code: |
IP20 |
ECG Lifetime: |
30,000h or 3 years Fail rate <10% |
(Remark) |
at use of Under normal conditions |
Cable cross section input side & output side |
0.5-2.5mm |
(Remark) |
Solid and flexible |
Wire preparation length Input side & output side |
7-8 mm |
Geometry (l x b x h): |
155x 41x 14.5mm |
Weight: |
142 g |
Safety Standard: |
GB9510.14-2009 GB9510.1-2009 |
EMI interference: |
GB17743 |
Harmonic content: |
IEC 61000-3-2 |
Immunity: |
IEC 61000-3-3,IEC 61547 |
Surge capability: |
L-N: 500V |
Galvanic isolation |
3,75 kVrms |
primary/secondary : |
SELV-equivalent |